|  9AM - 6PM M-F (CDT)

Uni-chem Chemical Reagents Certificate Of: Analysis

Most Uni-Chem reagent bottles now feature a QR code on the label.

A typical Uni-Chem CoA contains the following sections:

| Component | Description | |-----------|-------------| | Product Name & Code | e.g., “Uni-Chem Sodium Chloride, AR Grade, Cat# UC-1001” | | Batch/Lot Number | Unique identifier for traceability | | Manufacturing Date | Date of production | | Retest/Expiry Date | Recommended date for re-analysis | | Appearance | Physical description (white crystalline powder, clear liquid, etc.) | | Assay (Purity) | Percentage purity (e.g., ≥99.5% by titrimetry) | | Identity Tests | Confirmation via IR, Na⁺/Cl⁻ spot tests, or retention time (HPLC) | | Impurities | Limits for chlorides, sulfates, heavy metals (as Pb), iron, etc. | | Loss on Drying | Moisture content (e.g., ≤0.5% w/w) | | Residue on Ignition | Non-volatile inorganic residue | | Solubility | Compliance with specification | | Test Methods | References to standard procedures (AOAC, USP, in-house) | | Signature/Approval | Quality control officer’s name and date |

Chemical reagents must meet defined quality criteria to produce reliable experimental results. Uni-Chem, as a manufacturer of laboratory reagents, provides a CoA with each batch. The CoA serves as a legally binding guarantee from the manufacturer to the end-user, certifying that the product has been tested according to specified methods and meets stated limits.

The Uni-Chem COA is a controlled, lot-specific document issued by our ISO/IEC 17025 accredited quality control laboratory. It serves as the definitive "birth certificate" for each batch of chemical reagent, providing empirical data that validates its specifications.

Every Uni-Chem COA legally certifies:

This is the heart of the document. It is usually a two-column (sometimes three-column) table: Test, Specification, and Result.

| Test | Specification | Result (Example) | | :--- | :--- | :--- | | Appearance | Clear, colorless liquid | Conforms | | Assay (GC) | ≥ 99.9 % | 99.95 % | | Water Content (KF) | ≤ 0.02 % | 0.008 % | | Residue after Evaporation | ≤ 0.0005 % | 0.0001 % | | UV Absorbance (200nm) | ≤ 0.05 AU | 0.03 AU |

What Uni-Chem tests for (varies by reagent type):

A chemical is just a molecule. A Uni-Chem Chemical Reagent with its Certificate of Analysis is a certified tool for discovery.

“Trust, but verify. With Uni-Chem, verification is just a scan away.”


Need a specific COA for an audit?
📧 Contact Uni-Chem Quality Support at qa@uni-chem.com (Include product code and batch number).

To obtain a Certificate of Analysis (COA) for Uni-Chem chemical reagents, you typically need to access the manufacturer's specific search portal or contact their support team with your product's lot or batch number. How to Retrieve a Uni-Chem COA

While "Uni-Chem" can refer to several regional entities, the most direct methods to find documentation are:

Online Search Portals: Most major laboratory suppliers provide a dedicated search tool. For example, if you are using products from United Chemical (UCT), you can use the UCT COA Search by entering the lot number found on the product label.

Direct Contact: For Uni-Chem entities that do not have an automated online database, such as the Belgrade-based Uni-Chem d.o.o., you may need to request the document via their contact page or by calling their technical department at +381 11 3282 986. uni-chem chemical reagents certificate of analysis

Product Detail Pages: Some suppliers, like Spectrum Chemical, attach the COA directly to the specific chemical’s product page under a "Resources" or "Documents" tab. What is Included in the COA?

A COA serves as a "report card" for a chemical batch, verifying it meets specific quality standards. It typically includes: How to Read a Chemical Certificate of Analysis (COA)

A Certificate of Analysis (CoA) for Uni-Chem chemical reagents is a batch-specific document that verifies the chemical identity, purity, and quality of a specific lot. It ensures that the reagent meets the required standards (e.g., ACS, AR, or USP grades) for laboratory and industrial applications. 1. Key Information in a Uni-Chem CoA

The document typically includes the following critical data points to ensure traceability and research integrity:

Product Identification: Full chemical name, molecular formula, molecular weight, and CAS Number (a unique identifier to prevent confusion with similar compounds).

Lot/Batch Information: A unique Lot Number that must match the label on your physical container. It also includes the Manufacturing Date and Expiry/Retest Date to manage shelf life. Analytical Results:

Assay/Purity: The actual percentage of the active substance (e.g., ).

Parameters: Specific tests conducted, such as water content (Karl Fischer), trace metal analysis, or pH levels.

Specifications vs. Results: A comparison of the manufacturer's acceptable limits against the actual measured value for that specific batch.

Approval & Authentication: Signed (digitally or physically) by an authorized quality control representative, often including an electronic approval statement. 2. Common Reagent Grades Provided

Uni-Chem reagents are often categorized by purity level to match specific experimental needs: Grade Description AR / Analytical Reagent High purity (typically ) with strictly controlled impurities. Precision research, titrations, and quality control labs. ACS Grade Meets or exceeds American Chemical Society standards. Food, drug, or medicinal use; high-stringency applications. Extra Pure High-quality chemicals meeting pharmacopoeial standards. Laboratory accreditations and pharmaceutical testing. 3. How to Obtain a Uni-Chem CoA

To access the specific certificate for your reagent, follow these steps:

Locate the Lot Number: Find the batch or lot code printed on the product label.

Use the Online Search: Visit the official manufacturer portal (such as the UCT CoA Search) and enter the lot number.

Download PDF: Once found, you can download the document for your records. Most Uni-Chem reagent bottles now feature a QR

Contact Support: If the lot is not found online, email the supplier's customer service with the product code and lot number. 4. Why it Matters for Your Lab How to Read a Chemical Certificate of Analysis (COA)

Overview

The Uni-Chem Chemical Reagents Certificate of Analysis (CoA) is a document provided by Uni-Chem, a leading manufacturer and supplier of chemical reagents, to guarantee the quality and purity of their products. The CoA is a critical document that provides detailed information about the chemical composition, properties, and testing results of their reagents.

What's included in the Certificate of Analysis?

The Uni-Chem Chemical Reagents CoA typically includes the following information:

Importance of the Certificate of Analysis

The Uni-Chem Chemical Reagents CoA is essential for several reasons:

Uni-Chem's Commitment to Quality

Uni-Chem's commitment to quality is reflected in their rigorous testing and analysis procedures, which ensure that their reagents meet the required standards. The company's quality control process involves:

Conclusion

The Uni-Chem Chemical Reagents Certificate of Analysis is a valuable document that provides assurance of the quality and purity of their reagents. By including detailed information on chemical composition, properties, and testing results, Uni-Chem demonstrates their commitment to quality and customer satisfaction. The CoA is essential for customers who require high-quality reagents for various applications, including research, pharmaceuticals, and biotechnology.

The Ultimate Guide to Understanding Uni-Chem Reagent Certificates of Analysis (CoA)

In the precision-driven world of laboratory research and industrial manufacturing, a chemical reagent is only as good as the documentation backing it up. For professionals using products, the Certificate of Analysis (CoA)

serves as the definitive "report card" for every batch, bridging the gap between theoretical specifications and actual laboratory performance.

Whether you are conducting a high-stakes pharmaceutical assay or routine quality control, understanding how to decipher this document is critical for ensuring experimental reproducibility and regulatory compliance. What is a Uni-Chem Certificate of Analysis? “Trust, but verify

A Uni-Chem CoA is a batch-specific document that verifies the identity, quality, and purity of a chemical reagent. Unlike a general product specification sheet—ซึ่งบอกคุณว่าผลิตภัณฑ์ควรเป็นอย่างไร—the CoA provides real-world test results for the specific lot in your hand.

Uni-Chem operates under rigorous international standards, including ISO 9001:2015

, ensuring that each CoA is generated following strict quality management protocols. Anatomy of a Uni-Chem CoA

Every Uni-Chem certificate is structured to provide immediate clarity. Here are the core sections you will typically find: 1. Product Identification & Traceability

This header section ensures you have the right material for your project: Product Name & Grade:

Clearly states the chemical and its intended use (e.g., ACS Reagent, HPLC Grade, or AR Grade). Lot/Batch Number:

The most vital piece of info for traceability. This unique ID links your bottle to the original production run and testing data. CAS Number:

The universal identifier for the chemical substance, preventing naming confusion. 2. Key Date Tracking Manufacturing Date: When the batch was synthesized or purified. Retest or Expiry Date: Crucial for inventory management. The Retest Date

indicates when the manufacturer recommends re-verifying the chemical's quality to ensure it still meets the required specifications. 3. Analytical Test Results

This is the heart of the document, typically presented in a table format: Parameters:

The specific attributes tested, such as purity (Assay), moisture content (Karl Fischer), pH, or trace metal levels. Specifications:

The "pass/fail" limits set by Uni-Chem or industry standards like the American Chemical Society (ACS). Actual Results: The numerical values obtained during laboratory testing. Explain with an Image Visualize a chemical CoA structure Create visual Why This Document Is Non-Negotiable

Certificate of Analysis (COA) คืออะไร - Apex Chemicals

Scenario: A biotech in Boston was using a discount reagent supplier for their cell culture media preparation. During a critical HPLC run to quantify a monoclonal antibody, they saw ghost peaks interfering with their analysis.

The Problem: When they requested the CoA from the discount supplier, they received a generic “Certificate of Suitability” with no batch number. They could not trace the impurity.

The Fix: They switched to Uni-Chem HPLC-grade water and Acetonitrile. Upon arrival, they scanned the QR code, downloaded the batch-specific CoA, and noticed the UV absorbance specification was tighter (≤0.005 AU vs the previous 0.05 AU).

The Result: The ghost peaks disappeared. The lab manager now requires a Uni-Chem CoA to be printed and attached to every batch log sheet before use.


Go to Top