| OS | Version | 32-bit | 64-bit | |----|---------|--------|--------| | Windows 11 Pro/Enterprise | 21H2+ | No | Yes | | Windows Server 2022 | Standard/Datacenter | No | Yes | | Windows 10 IoT LTSC 2021 | 21H2 | No | Yes |
Deprecated: Windows 7, Windows 8.1, Windows Server 2016, and Windows 10 versions prior to 21H2.
These notes are a representative summary. Always verify with Rockwell Automation’s official documentation before deployment in a production environment.
Studio 5000 V35 introduces significant productivity enhancements, expanded hardware support for process industries, and a major push toward virtualization with the new Axis Test Mode. Key Highlights of Studio 5000 V35 Studio 5000 V35 Release Notes
Axis Test Mode: This major new feature allows developers to simulate real-time motion control without physical hardware. It supports ControlLogix 5580, CompactLogix 5380, and CompactLogix 5480 controllers, enabling testing of motion profiles via FactoryTalk Logix Echo.
Process Industry Expansion: V35 extends SequenceManager support to the 5x80P process controllers, allowing users to leverage high-performance process technology for batch and sequence applications.
First Public SDK: For the first time, Rockwell is offering a publicly available Studio 5000 Logix Designer SDK. This allows advanced users to automate repetitive tasks and integrate with digital twin software using C++ scripts. New and Enhanced Features | OS | Version | 32-bit | 64-bit
Studio 5000 V35 focuses on streamlining workflows and providing deeper integration for complex systems. 1. Advanced Motion Virtualization
The Axis Test Mode is designed for Kinetix, PowerFlex, and iTRAK 5730 CIP Motion devices. It lets you experiment with motion logic during the design phase, drastically reducing the risk of hardware damage during initial testing. 2. New Embedded Process Instructions
To further support PlantPAx and process applications, four critical instructions have been added: ATAN2: Two-argument arctangent for precision math. Deprecated : Windows 7, Windows 8
PD4SD: Controls 2-, 3-, or 4-state discrete devices like multi-speed motors.
PNPOS: Manages circular or linear devices with up to 30 discrete positions.
PVLVMP: Dedicated instruction for Mix Proof Valves, including support for CIP (Clean-in-Place) and SIP (Sanitize-in-Place) operations. 3. Productivity & UI Enhancements Release Note - Rockwell Automation Compatibility
Issue: The Verify Project command incorrectly flags some valid MQTT tags as "Unused."