Owon Hds2102s Firmware Update ◆
Once the scope boots to the normal waveform display:
Recent updates have added:
Verdict: If your version number is below v1.3.0, you need to update.
| Version | Notes | |-----------|-----------------------------------------------------------------------| | 1.0.1 | Early production | | 1.1.2 | Improved FFT stability, fixed trigger holdoff issue | | 1.2.0 | Added waveform recording/playback, better LAN stability (if equipped) |
These are examples — actual version numbers vary by hardware revision.
Based on OWON’s 2026 roadmap, look for the following in upcoming firmware versions:
If you use your HDS2102S for automotive CAN bus diagnostics, wait for the specific “v2.0.X” release expected Q3 2026.
On the HDS2102S:
OWON does not always list firmware publicly on their main product page. Recommended sources:
⚠️ Ensure the file is specifically for HDS2102S (not HDS272S or HDS242S).
The Owon HDS2102S Go to product viewer dialog for this item.
is a highly regarded 3-in-1 handheld oscilloscope, but its firmware update landscape is famously complex due to rapid hardware iterations and version-specific constraints. To successfully update your device, you must match your current firmware version to the correct update path, as installing incompatible firmware can render the device inoperable or cause display issues like inverted screens. Identifying Firmware Compatibility
Owon utilizes several distinct firmware branches based on the device's hardware revision (PCB and flash chip version). It is critical to check your current version in the System Menu before attempting an update:
V1.x.x Series: Typically found on earlier HW 1.0 boards. Updates like V1.5.1 are known to fix critical display spacing issues at fast time bases (2ns/div).
V3.x.x & V4.x.x Series: These represent different hardware generations. Users with V4 firmware should not attempt to "downgrade" to V1 or V2 versions found on some support sites, as these branches are not cross-compatible.
V8.x.x Series: Found in the newest 2024/2025 hardware revisions, which may include features like True RMS.
Hardware Note: Some early units with "Gigadevice" flash chips may have read-only OTP SecureRom, making them essentially non-upgradable. The Update Process
Once you have obtained the correct firmware file (often named Scope.upp), you can follow these standard steps:
Enter Upgrade Mode: On the oscilloscope, press the System button, navigate to the second page of the system menu, and select Upgrade. owon hds2102s firmware update
Enable USB Mass Storage: Set the USB mode to MSC (Mass Storage Class). When connected to a PC, the device should appear as a removable disk.
Transfer Firmware: Copy the .upp file directly to the root directory of the oscilloscope's removable disk.
Execute Update: Turn the device off and then back on. The oscilloscope will automatically detect the file, begin the flashing process, and shut down upon completion.
Verification: Restart the device and return to the System menu to confirm the version number has changed. Potential Risks and Troubleshooting
Updating test equipment carries inherent risks. Users have reported issues such as the LCD display turning upside down after installing firmware intended for a different hardware variant. If the official OWON Download Center does not list a version higher than your current one, the manufacturer generally advises against attempting an update. For persistent connection issues on Linux, you may need to manually detach kernel drivers to allow the update software to claim the USB device. What is the latest FW version for OWON HDS2102s? - EEVblog
Updating the firmware on your OWON HDS2102S handheld oscilloscope can resolve known display discrepancies—such as incorrect horizontal graticule spacing at high speeds (2ns/div)—and improve overall measurement accuracy. Preparation Identify Current Version : On your device, press F2 (System)
, and navigate to the next page to view the current firmware version. Download Official Files : Visit the OWON Download Center and select the HDS200 Series HDS2102(S) model to download the latest update package. Verify Hardware Compatibility
: OWON updates are often dedicated to specific hardware revisions (e.g., V1 vs V2); ensure you enter your specific version number if prompted on the site. Update Steps Enable Mass Storage Mode Turn on the scope and press
On the second page of the system menu, select the USB mode as (Mass Storage Class). Connect to PC
Connect the device to your computer via a USB cable. It should appear as a removable disk (e.g., "H: drive"). Transfer Firmware Copy the downloaded firmware file (typically named ) directly to the root of the removable disk. Execute Flashing Turn the oscilloscope
The device will automatically recognize the file, begin the upgrade process, and typically power itself off once finished. Verify Update Power the device back on and check the menu to confirm the version number has changed. Alternative Method (Bootloader Mode)
If the "MSC" method is unavailable, some versions require a dedicated Update Tool Download the Firmware Upgrade Tool Owon Software page Install the necessary USB drivers on your PC.
Connect the scope, run the tool, and toggle the power to enter bootloader mode for flashing.
Do not disconnect the USB cable or power off the device manually during the flashing process, as this can brick the hardware. latest known stable version number for your hardware revision?
Updating the firmware on the OWON HDS2102S fixes critical display issues and adds system stability. Core Improvements
Display Fix: Corrects the 2ns/div display glitch present in earlier versions.
Stability: General UI and system-level performance enhancements.
Waveform Handling: Improved acquisition memory management when saving data to CSV. Deep Feature: Acquisition Memory Export Once the scope boots to the normal waveform display:
A powerful feature in recent firmware is the ability to export full acquisition memory as a CSV file to a PC.
Raw Data: Accesses the actual sample points, not just the screen pixels.
Cross-Platform: Works on Windows and Linux by treating the scope as a mass storage device.
Analysis: Users can open these files in spreadsheets for advanced calculation and graphing. How to Update
Check Version: Go to System ➜ System Info to find your current firmware.
Download: Get the matching update from the OWON Download Center.
Set USB Mode: Change the scope's USB mode from HID to MSC (Mass Storage).
Transfer File: Copy the firmware file (e.g., Scope.upp) directly to the scope's root directory.
Power Cycle: Restart the device to initiate the automatic update process.
Watch this step-by-step guide to resolve display issues and update your device's firmware:
Updating the firmware on your Owon HDS2102S handheld oscilloscope is a critical maintenance step to resolve display discrepancies, fix bugs, and occasionally unlock new measurement features. Why Update Your Owon HDS2102S Firmware?
Accuracy Fixes: Earlier versions (e.g., v1.50) suffered from a horizontal spacing bug at the setting, where signal periods were displayed incorrectly.
New Features: Recent firmware transitions (e.g., from v4.1.0 to v4.7.1) have introduced RMS measurements and support for ampere units for clamp meter users.
System Stability: Updates often address 2-channel trigger bugs and translation errors. How to Update Owon HDS2102S Firmware
The update process for the HDS200 series typically involves using the device in "Mass Storage Class" (MSC) mode.
Check Current Version: Turn on your device, press the System button, and navigate to the System menu to view your current version.
Download Firmware: Visit the official Owon Download Center. You may need to enter your current version number to see compatible updates.
Note: If no update appears on the site, contact info@owon.com.cn with your serial number and current version to request the latest file. Recent updates have added:
Prepare the Device: Connect your HDS2102S to a PC via a USB-C to USB-A cable.
Tip: If the PC doesn't recognize the scope, try flipping the USB-C connector, as some ports are not symmetric.
Enter MSC Mode: Press System and set the USB mode to MSC. Your scope will appear on the PC as a removable drive.
Transfer the File: Copy the firmware file (typically named Scope.upp or similar) to the root directory of the scope's removable drive.
Execute Update: Turn the scope off, then back on. The device should automatically detect the update, perform the flash, and then turn itself off again. Critical Compatibility Warning
Firmware for the HDS2102S is strictly hardware-version bound. OWON HDS 200 Handheld Oscilloscope w/ builtin DMM/AWG
Updating the Owon HDS2102S firmware requires matching the software to your device's specific hardware version, as newer units may ship with versions (e.g., V4.3.0) that appear "newer" than those available on official download portals (e.g., V1.5.1). Latest Firmware Status Official Version : V1.5.1 is the most widely documented stable update on the Owon Download Center
: Version 1.51 reportedly fixes a display discrepancy at the horizontal range where graticules were incorrectly spaced. Hardware Conflicts : Users have reported receiving new units with ; experts advise against downgrading
these to V1.5.1, as different hardware revisions (specifically flash chip changes) may be incompatible. Update Procedures
There are two primary methods depending on the firmware file type provided by Owon Support Method 1: USB Drive (Using .upp files) Preparation : Format a USB drive and copy the file into a folder named (if required by your version). Device Setup : Turn on the scope, press F2 (System) Connection : Set USB mode to
(Mass Storage Class) to connect to a PC, or insert the drive directly if using an adapter.
: Power cycle the device. The scope should detect the file, perform the upgrade, and shut down automatically. Method 2: PC Launcher (Using .exe tools) Connection : Connect the scope to a PC via USB cable. Launcher.exe update tool and select your language. Bootloader Mode
: Click the update button in the software, then turn the scope off and back on to enter bootloader mode for flashing. Verification : Once finished, check the version number in the Important Precautions Check Serial Number
: Firmware updates for the HDS series are often tied to specific serial number ranges (e.g., 2152xxx for HW 3.1). : Installing incompatible firmware can lead to an upside-down screen or a bricked device. Official Advice
: Owon support has sometimes advised users not to upgrade if a newer version is not explicitly listed for their specific serial on the website. current hardware version to see if an update is recommended for your specific unit?
Here’s a structured, useful answer regarding OWON HDS2102S firmware updates — including where to find them, how to check your current version, and key precautions.
A: Rarely. They release “readme.txt” files in Chinese. Use Google Translate. Typically: